Abstract

A simulated workplace study was conducted to investigate the relation between inhalation exposure and dustiness determined with a rotating drum dustiness tester. Three powders were used in the study, i.e. magnesium stearate, representing a very dusty powder, and aluminium oxide and calcium carbonate, representing low and very low dusty powders, respectively. Two scenarios of handling small volume of powders were included; sweeping/cleaning and scooping/weighing/adding. Size-selective dust exposure was assessed using MultiDust (dual-fraction) IOM and RespiCon sampling heads. For the present operation scenarios, dustiness showed itself to be the major determinant of exposure and explained approximately 70% of the exposure variances. The ratios of respirable and inhalable fractions as determined by dustiness tests were comparable with the ratios observed for exposure. The results emphasize the relevance of dustiness as a parameter to characterize substances according to potential for exposure.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.