Abstract

This Letter presents a means of measuring the dipole orientation of a fluorescent, orientationally fixed single molecule, which uses a specially designed phase mask, termed a "quadrated pupil," conjugate to the back focal plane of a conventional wide-field microscope. The method leverages the spatial anisotropy of the far-field emission pattern of a dipole emitter and makes this anisotropy amenable to quantitative analysis at the image plane. In comparison to older image-fitting techniques that infer orientation by matching simulations to defocused or excessively magnified images, the quadrated pupil approach is more robust to minor modeling discrepancies and optical aberrations. Precision of 1°-5° is achieved in proof-of-concept experiments for both azimuthal (φ) and polar (θ) angles without defocusing. Since the phase mask is implemented on a liquid-crystal spatial light modulator that may be deactivated without any mechanical perturbation of the sample or imaging system, the technique may be readily integrated into clear aperture imaging studies.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.