A simple, effective, and environmentally friendly sample preparation method was developed by using dispersive liquid–liquid microextraction prior to high‐performance liquid chromatography analysis for the extraction/concentration and assay of nonsteroidal anti‐inflammatory drugs (NSAIDs), including indoprofen, ketoprofen, naproxen, diclofenac, ibuprofen, mefenamic acid, and tolfenamic acid, from an aqueous sample. The extraction conditions were optimized with respect to several experimental parameters (dispersive solvent, extraction solvent, pH, salt additive, and concentration) for the simultaneous extraction and analysis of NSAIDs by the response surface methodology based on the central composite design method. The limit of detection and limit of quantitation of the spiked sample were in the concentration range of 0.65–1.3 and 2.2–4.4 µg/L, respectively. The accuracy and precision in the working range were 85–106% and 0.5–10.4% (relative standard deviation), respectively. The linear equations for quantitative analysis were in the concentration range of 0.5–5.0 µg/L with correlation coefficients (R 2 = 0.9990–0.9996).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.