Abstract

A reversed-phase HPLC method for the simultaneous quantitative determination of mandelic acid enantiomers (MA) and phenylglyoxylic acid (PGA) in urine is described. MA and PGA were extracted with ethyl acetate from urine at acidic pH and derivatized with S-(-)-1-(1-naphthyl) ethylamine. A ZORBAX SB-C(18) column (250 mm x 4.6mm i.d., 5 microm, Agilent, USA) was used with a mobile phase composed of methanol-10 mmol/L phosphate buffer [pH 2.5 (65:35, v/v)] at a flow-rate of 0.8 ml/min. Detection was set at UV wavelength of 254 nm. The mean absolute recoveries were 94.2%, 91.9%, 92.5% and 86.3% for S-MA, R-MA, PGA and salicylic acid (I.S.), respectively. The intra- and inter-day precisions determined at three different concentrations ranged from 2.8% to 4.8%, 0.7% to 7.7% and 1.3% to 6.8%, respectively. The lower limits of detection for MA enantiomers and PGA in urine were 1 microg/ml and the lower limits of quantification were 5 microg/ml (R.S.D.<10%, n=5). The method has been applied to determine the urinary excretion of MA enantiomers and PGA from Sprague-Dawley rats after orally administered with styrene.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.