Abstract

A sensitive liquid chromatography–electrospray tandem mass spectrometry method combined with solid-phase extraction and silica cartridge cleanup was established for 16 sulfonamides and trimethoprim in various water matrices. Signal suppression of all target analytes in sewage treatment plant influent, effluent and river water was improved by this method developed in this study. The method detection limits for 17 analytes were 20–200 pg/L for influent, 16–120 pg/L for effluent and 8.0–60 pg/L for river water with overall mean recoveries of 62–102% in all studied matrices. This method was used to analyze residual sulfonamides and trimethoprim in wastewater and river samples from Japan, and 8 analytes (0.08 (sulfadimethoxine)–161 ng/L (sulfapyridine) in wastewater and 10 (0.03 (sulfamethizol)–8.9 ng/L (sulfaquinoxaline) in river samples were detected.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.