Abstract

This paper presents a reconstruction model of three-dimensional temperature distribution in furnace based on radiative energy images captured by charge-coupled device (CCD) cameras within the visible wavelength range. Numerical simulation case was used in this study and a zigzag eccentric temperature distribution was assumed to verify the model. Least square QR-factorization (LSQR) method was introduced to deal with reconstruction equation. It is found that the reconstructed temperature distributions in low-temperature areas had some fluctuations and high-temperature areas were reconstructed well. The whole reconstruction relative error was mainly due to errors in low-temperature areas and the relative error for highest-temperature reconstruction was quite small.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.