Abstract

Post-earthquake fire (PEF) is one of the most complicated problems resulting from earthquake, presenting a serious risk to urban buildings. As most standards and codes ignore the possibility of PEF, buildings are too weak under PEF loads. This chapter is to investigate the effects of PEF loads on partially damaged RC buildings located in urban regions. To do that, a methodology named sequential analysis is introduced here via which the structural performance at various performance levels is evaluated under fire and PEF scenarios. Numerically, in order to simulate the earthquake loads, conventional pushover analysis is employed, with an explanation presented in the chapter to introduce the pushover analysis, its advantages and its limitations. To simulate the fire loads, standard fire curve (ISO 834) is used for simplicity.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.