Abstract

A simple and extractionless HPLC method using fluorescence detection was developed for the determination of rosiglitazone in human plasma. After deproteinization using perchloric acid the plasma samples were directly injected onto the HPLC system. The mobile phase was composed of acetonitrile (52%) and 20 mm ammonium acetate (48%, pH 7.5), and analysis was run at a flow rate of 0.2 mL/min with the detector operating at 247 nm for excitation wavelength and at 367 nm for emission wavelength, respectively. The method has a mean recovery of 97%, while the intra-day and inter-day precisions were all less than 7%. This method is simple, specific, sensitive and requires only a small plasma volume with short analytical time, and is suitable for the determination of plasma rosiglitazone in routine measurements for pharmacokinetic studies.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.