Abstract

Silicone rubber (polydimethyl siloxane) tubes are used clinically in peripheral nerve reconstruction. A disadvantage of this procedure is that the material often has to be removed owing to its mechanical properties. The aim of our study was to investigate the healing of reconstructed sensory nerves tubulized by silicone rubber in an animal model. In our experiments, we reconstructed the saphenous nerves in 27 rabbits. In series 1 (n = 12), silicone rubber tubes were slid over a nerve suture without a gap. In series 2 (n = 12), silicone rubber tubes were slid over a 10-mm nerve gap. In series 3 (n = 12), conventional suturing was performed in the collateral saphenous nerves of the animals of the series 1. Epineurial suturing was performed. Three other collateral nonoperated saphenous nerves served as controls. The healing was studied after 3, 6, and 12 months. Morphometric analysis of the regenerating axons was performed by using our new method for quantification of nerve fibers in cross sections stained by immunohistochemistry and using confocal laser scanning microscopy. Data analysis was carried out using a software program especially developed for this purpose. Our results showed in the silicone procedures that at 12 months significantly fewer axons per fascicle area were present compared with conventional suturing. However, mean axon diameters in the distal nerve stump of the silicone procedures did not differ significantly compared with the conventional suturing procedure. The ratio of total axon area to total fascicle area in the distal nerve stumps of the silicone procedure without gap was significantly smaller compared with the conventionally sutured nerve. The percentage outgrowing axons from the proximal nerve stump into the distal one in the silicone rubber procedure without gap was 57%. This was significantly higher than in the silicone rubber procedure with 10-mm gap (48%). However, in conventional suturing, the percentage of outgrowing axons (99%) was significantly higher than in both tubulization procedures. It appeared that tubulization by silicone rubber of sutured nerves without gap did not enhance axon regeneration. Conventional suturing gave significantly better results. If a gap was present, the use of a silicone rubber tube was preferable to non-suturing.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.