Abstract

Abstract. The heating of drinking water in households contributes significantly to the emission of greenhouse gases. As a water utility aiming to operate at a climate neutral level by 2020, Waternet needs to reduce its CO2 emission by 53 kton yr−1. To contribute to this ambition, a pilot project was carried out in Uilenstede, Amstelveen, the Netherlands, to recover the shower heat energy with a shower heat exchanger from Dutch Solar Systems. An experimental setup was built in the Waternet laboratory to evaluate the claimed efficiencies. The energy recovery efficiency observed in the lab was 61–64 % under winter conditions and 57–62 % under summer conditions, while the energy recovery efficiency observed in Uilenstede was 57 % in December 2014. Based on the observations, 4 % of the total energy consumption of households in Amsterdam (electricity and gas) can be recovered with a shower heat exchanger installed in all households in Amsterdam, which also means a 54 kton year−1 CO2 emission reduction can be achieved.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.