Abstract

Three dimensional Born and Kirchhoff inverse scattering methods are modified to convenient forms for a cylindrical specimen that includes three dimensional defect. One aluminum cylinder with flaw model is prepared and ultrasonic measurements are carried out. The measurement area in the modified methods is restricted in the plane perpendicular to the axis of cylindrical specimen. That is to say that the methods are modified to convenient form to use measured waveforms in the x 1– x 2 plane. The measured wave data are fed into the inversion method and cross-sectional images are obtained. Then, three dimensional shape reconstruction of flaw model in aluminum specimen is performed by piling up the cross-sectional images.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.