Abstract
Although many authors have reported the serum concentrations of metal ions in patients who had metal-on-metal coupling prostheses, most of the studies were not longitudinal, and the follow-up periods were short. We evaluated the longitudinal changes of serum chromium levels in 44 patients who had undergone unilateral metal-on-metal total hip arthroplasty for a minimum of 7 years postoperatively. Although there was a consistent increase in the mean serum chromium level until 3 years after implantation, there was little difference in the levels from years 3 to 7 postoperatively. Although the serum chromium concentration was low throughout postoperative follow-up for 7 years in about 25% of patients, the serum chromium level stayed high or showed gradual elevation in 16.3% of our patients.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.