Abstract

When a nickel cathode is used during electrolysis, the separation factor {gamma} of D{sub 2}O/T{sub 2}O is measured and found to be 2. When a platinum cathode is used, the value of {gamma} is found to also be 2. This value is the same as the value that was measured and reported in an earlier paper that dealt with the use of a palladium cathode. A mathematical model that predicts the tritium concentration in the electrolysis cell finds the predictions to be in agreement with the measured values of tritium concentration in the cell. Excess tritium concentration is observed in the recombined off-gases in the case of the nickel cathode. 3 refs., 2 figs., 2 tabs.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.