Abstract

This paper presents a method of estimating pole position of interior permanent magnet synchronous motors, IPMSMs. The proposed method estimates the pole position at low speeds and standstill by measuring only the DC link current of the inverter. The pole position is estimated by using the saliency of the IPMSMs. In order to detect the saliency, the three phase triangular carrier waves are used. The DC link current is measured at tops and bottoms of the carrier waves. Experimentation is performed to confirm the validity of the proposed method.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.