Abstract

The aim of this paper is to present a sensor fault-tolerant control (FTC) scheme for a two-axis fast steering mirror (FSM) system with minimum power consumption and without changing the controller structure. In this paper, an adaptive PI-based sliding mode observer (APISMO) is adopted firstly to estimate the fault signal, which does not require any prior knowledge of the fault. The estimation is then used by the fault isolation logic to identify the fault. The redundant sensor would be powered up to replace the faulty one when faults occur. During the backup sensor booting up, for maintaining the normal performance of the closed-loop system approximately, a fault-free estimation of the position provided by the APISMO is used as feedback signal. Experimental studies on a prototype system show that the proposed APISMO can effectively reconstruct the fault signals even when the two primary position sensors are faulty simultaneously. Meanwhile, the effectiveness and performance of the proposed scheme have been verified.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.