Abstract

A diagnostic protocol was developed for rapid detection of Vibrio corallilyticus by method of loop-mediated isothermal amplification (LAMP). For cloning and sequencing of rpo A gene of V. corallilyticus, a set of four LAMP primers were designed by targeting the rpoA gene. With Bst DNA polymerase, the reaction time and temperature were optimized for 70 min at 65 degrees C, respectively. The amplification products were detected by electrophoresis. The detection limit of V. corallilyticus by LAMP was 3.6 x 10(3) CFU ml(-1) (8 CFU per reaction), but PCR could detect up to 3.6 x 10(4) CFU ml(-1) (72 CFU per reaction). The LAMP method was ninefold more sensitive than conventional PCR. The results also indicated that the LAMP reaction was highly specific to V. corallilyticus. The LAMP assay was a sensitive, specific and cost-effective method for the rapid detection of V. corallilyticus. This LAMP method provides an important diagnostic tool for the detection of V. corallilyticus infection. It can replace laborious biochemical tests for the identification of V. corallilyticus.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.