A new amplified signal strategy for acetaminophen (AC) electrochemical sensor was explored by soluble zinc tetrahydroxyphthalocyanine-reduced graphene oxide nanocomposite as an improved electrode material via non-covalent functionalization. The electrochemical signal of AC was amplified by the remarkably increased electroactive surface area of the nanocomposite-modified glassy carbon electrode. Moreover, the synergistic enrichment effect can be achieved by the adsorption of π-π stacking and hydrogen bonding of hydroxyl groups. The prominent electrocatalytic effect toward AC oxidation were examined systematically on the proposed sensor and a sensitive and selective electroanalytical method for AC was developed. Under optimized conditions, the electrochemical response of the sensor exhibited a linear dependence on the concentration of AC ranging from 0.03 to 100 μM and 100 to 800 μM with a detection limit of 10 nM (S/N = 3). The proposed sensor with excellent selectivity, reproducibility and long-term stability for AC sensing was successfully applied for AC determination in drug formulation and human urine samples.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.