Abstract

A new semi-analytical procedure is derived for the determination of buckling of the reinforced concrete column exposed to fire. The fire analysis is performed in three separate steps, of which the time development of temperatures in the fire compartment is performed first, followed by the coupled heat and moisture transfer analysis and, finally, by the mechanical analysis. A particular emphasis has been given to the critical buckling time and the remaining critical buckling load at a selected time. For this purpose, a parametric study has been performed by which the influence of different geometric parameters on the buckling load capacity of reinforced concrete columns has been assessed. The results of this study show that the load-carrying capacity of the column reduces significantly with the increasing time of fire exposure and the column slenderness. Moreover, the initial mechanical load has a small, although not negligible effect on the buckling load capacity.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.