Abstract

Long chain alkanethiols self-assembled monolayers (SAMs) formed on Au microelectrodes showed higher sensitivity towards defects than the same monolayers on macroelectrodes. The analysis of cyclic voltammetry and electrochemical impedance spectroscopy (EIS) experiments performed on covered microelectrodes were consistent with the formation of pinholes of about 10 nm in diameter. Moreover, the EIS data exhibited a specific behavior that was interpreted invoking the short circuiting of the pinholes impedance by the surrounding surface of the microelectrode in the high frequency domain, whereas in the low frequencies, the surface covered by the SAM was assume to act as an insulator.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.