Abstract

A method for measuring the ultraviolet spectrum characteristic of Au photocathode has been put forward. Making use of the high gain characteristic of microchannel plate (MCP) and ultraviolet light, the frequency response of Au cathode has been studied by measuring the output current of Au coated MCP detector directly. Through measuring the response current of Au coated MCP detector between 200—340 nm, the selective photoemission of Au has been found, which had been found only for alkali metals. And the selective peak is at 5.72 eV, which can be explained by quantum mechanics theory.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.