Abstract

This research article proposed a new modified single-phase multi-level inverter topology with an optimal switching control strategy to reduce the inverter output harmonic distortion. The topology is configured to operate in asymmetric mode to generate eleven levels of output voltage steps. Additionally, a selective harmonic elimination technique has been deployed to minimize the switching loss and EMI. The Moth Flame Optimization (MFO) algorithm is deployed to compute the optimal switching angles. The proposed MLI topology is simulated in PSIM software using the optimized switching angles. The inverter performance parameters such as the total harmonic distortion (THD), harmonic amplitudes, switching, and conduction losses, were also analyzed and reported. The topology total harmonic distortion is 2.4%, hence satisfying the IEEE 519 standard.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.