Clenbuterol hydrochloride (CLB) is often abused as additive feed for livestock to decrease adipose tissue deposition and to increase growth rate. It raises a potential risk to human health through the consumption of animal product. In this study, aptamers with higher affinity and specificity were screened through 16 selection rounds based on the ssDNA library immobilized systematic evolution of ligands by exponential enrichment (SELEX) technique. After cloning and sequencing, five aptamer candidates were picked out for affinity and specificity assays based on a graphene oxide (GO) adsorption method. The results showed that the aptamer CLB-2 binds specifically against CLB with a dissociation constant, Kd, value of 76.61 ± 12.70 nM. In addition, an aptamer-based fluorescence bioassay was established for CLB analysis. The correlation between the CLB concentration and fluorescent signal was found to be linear within the range of 0.10 to 50 ng/mL with a limit of detection of 0.07 ng/mL. It has been further applied for the determination of CLB in pork samples, showing its great potential for sensitive analysis in food safety control.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.