Abstract

In the present study, seismic design of a bridge curved in plan has been done for various response reduction factors (R) and the performance has been investigated as per FEMA-356 performance based criteria. Both uni-directional and bi-directional nonlinear dynamic time history analyses have been performed for the bridge. The performance of the bridge in terms of pier ductility demand has been determined for Kobe earthquake ground motion, compatible for Design Basis Earthquake (DBE) and Maximum Considered Earthquake (MCE) response spectrums. For different values of R-factors, suitable value of safe pier diameter of the bridge has been determined. The strength reduction factor and over strength factor have also been determined for various cases considered. It has been obtained that the bi-directional effect increases the performance state and ductility demand of the bridge. The maximum R-factor of 2.5 can be recommended for the studied bridge.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.