Abstract

In February 1991, a type GT11N gas turbine (Midland, USA) was retrofitted with ABB’s new EV-Silo-Combustor. Tests were then carried out to examine the operation concept, to demonstrate the technical reliability, and to confirm the low emission performance of this new technology. This paper will describe: the combustor design—one single silo combustor mounted on the turbine and equipped with 37 Ev burners; and the results of the extensive field measurements—the operation concept (lean premix combustion without any pilot diffusion flames, 7 burner groups) is simple and reliable. The emission targets—NOx<25 ppmv (15 percent O2, natural gas), CO<8 ppmv, UHC<5 ppmv—were reached. NOx values are even lower than 15 ppmv at base load. The NOx predictions for the GT11N-EV, based on the results of high-pressure tests in Cologne (ASME Paper No. 90-GT-308), compared very well with the results of field measurements.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.