Abstract

This work deals with the seasonal daily variation of the operating temperature of silicon solar panels under tropical atmospheric conditions, including high turbidity (Harmattan dust particles). Data was collected from March 2010 to July 2012 at Legon (0°11′08″ W, 5°39'04″ N) using a Davis wireless Vantage Pro2 Plus weather station monitored with the software WeatherLink®. While the ‘common outdoor’ operating temperature is usually set at 45 °C, it has been observed that during the harmattan season, the operating temperature of a solar panel can rise beyond 70°C.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.