Abstract

Application of seasonal thermal energy storage with heat pumps for heating and cooling buildings has received much consideration in recent decades, as it can help to cover gaps between energy availability and demand, e.g. from summer to winter. This has the potential to reduce the large proportion of energy consumed by buildings, especially in colder climate countries. The problem with seasonal storage, however, is heat loss. This can be reduced by low-temperature storage but a heat pump is then recommended to adjust temperatures as needed by buildings in use. The aim of this paper was to compare different seasonal thermal energy storage methods using a heat pump in terms of coefficient of performance (COP) of heat pump and solar fraction, and further, to investigate the relationship between those factors and the size of the system, i.e. collector area and storage volume based on past building projects including residences, offices and schools.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.