Abstract
In this work, the influence of indenter tip radius (ITR) on scratch tests in boride layers was studied. The thermochemical treatment of boriding was performed on an AISI H13 steel at 1000 °C for 1 h. Depth sensing indentation test was developed to estimate both, hardness, and elastic modulus of the boride-layer/substrate system. Indenter radius of 200, 100, 50 and 20 μm were used for the scratch tests on borided steel. Failure mechanisms were analyzed by scanning electron microscopy (SEM). Predominant failure mechanisms were lateral cracking, chipping, and gross chipping. ITR of 20 μm developed more severe damage on the borided AISI H13 surface and the more severe substrate plastic deformation was obtained by ITR of 200 μm.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.