Control rod drop verification experiments of a pressurized water reactor under seismic conditions are performed to confirm the insertion function of control rods into a core. To evaluate these tests, computer simulations are performed. A fuel assembly, control rods, guide tube and other associated structures are immersed in a water tank, and shaken by four hydraulic shakers. The scram time of control rods under seismic conditions was measured, and confirmed to meet the scram function. Moreover, vibrational response characteristics of core structure and dropping behavior of control rods in consideration of collisions are calculated by using a finite difference method. The behavior of the dropping control rods and the scram time obtained by the computer simulation show a very good agreement with the verification experimental results.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.