Abstract

In this paper, we review our recent work to assess scanning capacitance microscopy (SCM) as a quantitative two-dimensional (2D) carrier profiling method on Si. SCM measurements on a wide variety of samples are discussed. In the case of unipolar Si samples (i.e. samples with a unique majority carriers type) the reliability of the method for quantification of the SCM raw data to carrier concentration profiles has been demonstrated. Angle beveling sample preparation allows quantitative carrier profiling with unprecedented depth resolution (1 nm), as demonstrated on specially designed samples containing B-doped Si/Si 0.75Ge 0.25/Si quantum wells. Applications to the study of the dopant diffusion and electrical activation of low-energy implanted B in submicron areas (0.38 μm) are shown. In the case of bipolar Si samples (i.e. samples containing electrical junctions), the crucial issue of electrical junction position determination both on cross-section and on bevel is addressed. Applications to a cross-sectioned 0.35 μm n–p–n transistor characterization are shown.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.