Abstract

BACKGROUND CONTEXTThe introduction and integration of robot technology into modern spine surgery provides surgeons with millimeter accuracy for pedicle screw placement. Coupled with computer-based navigation platforms, robot-assisted spine surgery utilizes augmented reality to potentially improve the safety profile of instrumentation. PURPOSEIn this study, the authors seek to determine the safety and efficacy of robotic-assisted pedicle screw placement compared to conventional free-hand (FH) technique. STUDY DESIGN/SETTINGWe conducted a systematic review of the electronic databases using different MeSH terms from 1980 to 2020. OUTCOME MEASURESThe present study measures pedicle screw accuracy, complication rates, proximal-facet joint violation, intraoperative radiation time, radiation dosage, and length of surgery. RESULTSA total of 1,525 patients (7,379 pedicle screws) from 19 studies with 777 patients (51.0% with 3,684 pedicle screws) in the robotic-assisted group were included. Perfect pedicle screw accuracy, as categorized by Gerztbein-Robbin Grade A, was significantly superior with robotic-assisted surgery compared to FH-technique (Odds ratio [OR]: 1.68, 95% confidence interval [CI]: 1.20–2.35; p=.003). Similarly, clinically acceptable pedicle screw accuracy (Grade A+B) was significantly higher with robotic-assisted surgery versus FH-technique (OR: 1.54, 95% CI: 1.01–2.37; p=.05). Furthermore, the complication rates and proximal-facet joint violation were 69% (OR: 0.31, 95% CI: 0.20–0.48; p<.00001) and 92% less likely (OR: 0.08, 95% CI: 0.03–0.20; p<.00001) with robotic-assisted surgery versus FH-group. Robotic-assisted pedicle screw implantation significantly reduced intraoperative radiation time (MD: −5.30, 95% CI: −6.83–3.76; p<.00001) and radiation dosage (MD: −3.70, 95% CI: −4.80–2.60; p<.00001) compared to the conventional FH-group. However, the length of surgery was significantly higher with robotic-assisted surgery (MD: 22.70, 95% CI: 6.57–38.83; p=.006) compared to the FH-group. CONCLUSIONThis meta-analysis corroborates the accuracy of robot-assisted pedicle screw placement.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.