Abstract

The present investigation highlights the role of solution hydrodynamics on the deposition of calcium sulfate scale on copper substrate. The study was carried out using a Rotating Cylinder Electrode (RCE) system at various pre-set rotational speeds, at 60 and 70°C on 120 and 600 grits polished cylindrical specimens. The effects of temperature, surface roughness, and flow conditions on the deposition of calcium sulfate scale on copper substrate are presented. The results indicate that the solution hydrodynamics play an important role on the rate of deposition of calcium sulfate scale on copper specimens. In addition, the analysis of scaling data further corroborated well with the theoretically predicted diffusion controlled process. Morphology of deposited crystals was obtained from scanning electron microscope (SEM) micrographs and composition was determined with energy dispersive X-ray spectrometer (EDS) method. SEM revealed prismatic needle- and rod-like crystals growth at nucleation sites branching out ...

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.