The close relationship between the locked mode (LM) and pulsed poloidal current drive (PPCD) regime in a reversed-field pinch device is described. If the modes lock close to the shell gap then the LM is enhanced and there is a high probability that the PPCD will not improve plasma performance. The physical reason will be discussed. If the position of the locked mode is far from the shell gap then the PPCD is effective with a high probability. LM energy is reduced and the more the LM energy decreases, the better the plasma performance.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.