Abstract

ABSTRACTThis article suggests a robust cascade speed control algorithm for a permanent magnet synchronous motor (PMSM) combining the classical feedback linearising (FL) method and the disturbance observers (DOBs) without the integrators. The contributions of this method are twofold. The first one is to provide the simple DOBs for not only guaranteeing the closed-loop performance recovery property but also removing the steady-state errors without the integrators with respect to the tracking errors. The second one is to prove that the inner and outer loops are stabilised by the proposed cascade-type controller, simultaneously. The simulation and experimental results reveal that the proposed method maintains the speed tracking performance to be satisfactory for a wide operating region with the fixed control gain despite a plant-model mismatch where a 3-kW interior PMSM is utilised.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.