Abstract

The aim of our study was to identify and compare risk factors for failure of retropubic and transobturator procedures. This was a retrospective cohort study. Women with predominant stress urinary incontinence who underwent a retropubic (n = 214) or transobturator tape procedure (n = 173) were included. Therapy was considered to have failed in women reporting any amount of urine leakage during stress after 2 and/or 12 months. Risk factors for failure were mixed urinary incontinence (MUI; odds ratio [OR], 3.7; 95% confidence interval [CI], 1.5-9.1) and the observation of detrusor overactivity (DO) at urodynamics (OR, 8.6; 95% CI, 1.9-39.4) in the retropubic group. Reporting a history of previous incontinence surgery (OR, 3.9; 95% CI, 1.3-11.7) and a low mean urethral closure pressure (MUCP) at urodynamics (OR, 14.5; 95% CI, 1.5-139.0) were risk factors for failure in the transobturator group. Women with previous incontinence surgery or a low MUCP might benefit more from a retropubic sling, whereas a transobturator procedure might be preferable in women with MUI or DO.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.