Abstract

Cage subsidence is a very common complication after lumbar interbody fusion. It may compromise vertebral interbody fusion through progressive spinal deformity and consequently cause compression of neural elements. Clinical relevance remains, however, unclear, with few studies on this subject and even less information regarding its correlation with clinical findings. The aim of this study was to identify risk factors for cage subsidence and clinical evaluation after transforaminal (TLIF) and posterior (PLIF) lumbar interbody fusion. A retrospective study in patients submitted to TLIF and PLIF between 2008 and 2017 was conducted. A total of 165 patients were included (123 TLIF and 42 PLIF). Univariate analysis showed an increased risk of cage subsidence in spondylolisthesis comparing with degenerative disk disease (p = 0.007). A higher preoperative lumbar lordosis angle (p = 0.014) and cage placement in L2-L3 (p = 0.012) were associated with higher risk of subsidence. The posterior cage positioning on vertebral endplate was associated with a higher risk of subsidence (p = 0.028) and significant subsidence (p = 0.005), defined as cage migration > 50% of cage height. PLIF presented a higher risk when comparing with TLIF (p = 0.024). Hounsfield unit (HU) values < 135 (OR6; 95% CI [1.95-34]) and posterior positioning (OR7; 95% CI [1.7-27.3]) were independent risk factors for cage subsidence and significant subsidence, respectively, in multivariate analysis. There was a tendency for significant subsidence in degrees ≥ 2 of Meyerding spondylolisthesis (OR4; 95% CI [0.85-21.5]). Significant cage subsidence was not associated with worse clinical results. Other analyzed factors, such as age (p = 0.008), low bone mineral density (BMD) (p = 0.029) and type of surgery (TLIF) (p = 0.004), were associated with worse results. The present study shows that lower BMD and posterior cage positioning are relevant risk factors for lumbar cage subsidence. Low BMD is also a predictor of poor clinical results, so it must be properly evaluated and considered, through HU values measurement in CT scan, a feasible and reliable tool in perioperative planning.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.