Abstract

Several European laboratories have combined their research efforts to arrive at a consensus view on using fluorescence in situ hybridisation (FISH) for retrospective dosimetry. The aim of this review is to report these views and to highlight some areas where further work is needed. Translocations in the stable cells should be measured only in the cells that contain the full complement of the painted material. Two-way and one-way translocations should be combined with equal weight. The control level of translocations has a strong dependence on age, which has now been measured and the system has been calibrated. In conclusion, the technique works and a lifetime dose to the bone marrow from low-linear energy transfer radiation of 0.5 Gy above normal background levels can be measured for any individual. The main application is considered to provide an independent verification of lifetime doses to individuals who might form a part of an epidemiological study.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.