Abstract

To the Editor, Image artifacts that emerge during diagnostic imaging include extraneous ultrasound signals appearing as structures that are not actually present or as structures that differ in size and/or shape from their actual appearance. Reverberations, an important source of artifacts in ultrasonography, are caused by the repeated back-and-forth reflections of an ultrasound wave between two strong specular reflectors. When the transducer reflects the strong echoes, they travel back to the original target. However, the transducer takes twice the time to detect this pulse than it does to detect the original pulse and, as a result, incorrectly places the target at twice the distance. Since this ‘‘second trip’’ duplicates the travel distance and the travel time, the targeted structure is imaged once at the correct distance and a second time at twice the distance from the transducer. As a result, an artifact is produced that appears as a duplication of the real structure. Cardiac anesthesiologists are familiar with reverberation artifacts. They recognize this phenomenon when they observe a double image of the heart (caused by reflection of the pericardium) while performing transesophageal echocardiography or transthoracic echocardiography. While most cardiac anesthesiologists are accustomed to such reverberatory effects, this manifestation may be less commonly recognized by anesthesiologists practicing regional anesthesia. Recently, while attaining supraclavicular ultrasound identification of the brachial plexus, we observed the subclavian artery image in the transverse scan presenting as the source for a reverberatory artifact. The vessel was correctly imaged in the near field and falsely duplicated below (Fig. 1). More interestingly, the illusion of the subclavian artery was clearly visualized below the pleural line, creating a mirror-like image of the vessel within the lung. Immediate recognition of the artifact was instrumental to ensuring a successful block and an uneventful outcome. In conclusion, ultrasound reverberations can potentially result in misinterpretation of the ‘‘real’’ image during

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.