Abstract

Spent fluorescent lamps glass (SFLG) waste, manually and mechanically processed in a lamps waste treatment plant, was used to partially replace up to 50 wt% Portland cement (PC). Both waste types exhibited similar pozzolanic activity. The mortars containing up to 35 wt% SFLG met the specifications for other pozzolanic materials (e.g. fly ash) and, after 90 curing days, their compressive strength values were similar to or higher than those of the 100% PC sample (58.8 MPa). Our results provide an alternative reutilization process for this hazardous waste to reuse SFLG as-received (no washing to reduce mercury) and contributes to less PC use.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.