Abstract

We performed a retrospective analysis of flow cytometry as a platelet crossmatching procedure. Sera from 17 alloimmunized refractory patients were tested against 32 donor platelets, which had been stored as platelet-rich plasma for up to 36 months. Overall, 14/32 (44%) crossmatches were positive. The mean 1 h posttransfusion corrected count increments (CCIs) were 9,195 and 2,269 for a negative and a positive crossmatch, respectively. The predictive value of a positive crossmatch was 86%, whereas the predictive value of a negative crossmatch was 56%. When samples with low background fluorescence or with high panel-reactive antibody (PRA) levels were evaluated separately, the accuracy of the crossmatch improved from 69% to 80%. When compared to the platelet adhesion immunofluorescence test (PAIFT) and the standard and antiglobulin-enhanced lymphocytotoxicity tests for the detection of HLA antibodies, flow cytometry appeared to be more sensitive. We conclude that flow cytometry is a useful technique for platelet crossmatching, particularly for alloimmunized patients for whom HLA compatible platelets may not be readily available.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.