Abstract

The results of balloon aortic valvuloplasty (BAV) in 218 adult patients with valvular aortic stenosis (AS) are reported. In most cases, 3 transcutaneously introduced balloons of successively increasing size were used. Tolerance was excellent in 64%, whereas a decrease in blood pressure below 60 mm Hg during inflation was observed in 36%. The left ventricular-aortic peak to peak gradient decreased from 72 ± 25 to 29 ± 14 mm Hg (p < 0.001) and the aortic valve area increased from 0.52 ± 0.18 to 0.93 ± 0.33 cm 2 (p < 0.001). The final aortic valve area was ≥1 cm 2 in 69 patients (32%). In only 6 cases (3%) the aortic valve area did not change or increased by <10%. A clear improvement in the results was observed with gained experience and better catheters. There was 1 death and 1 stroke in the procedure room, and 3 strokes after BAV. Nine patients died shortly after the procedure. There were local complications (hematoma or thrombosis) at the femoral puncture site in 28 (13%) patients. Clinical follow-up was obtained for 144 patients (mean 8 months). There were 24 deaths. In the 120 remaining cases, symptomatic improvement was good in 84%, with decrease or disappearance of dyspnea, angina or both. This study demonstrates that BAV is feasible in adult AS at a low risk and is able to produce marked clinical improvement in most cases.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.