Abstract

Three 0.5% cold-leg small-break loss-of-coolant accident (SBLOCA) experiment were conducted at the ROSA-IV Large Scale Test Facility (LSTF) to investigate the effects of break orientation on system thermal-hydraulic responses. In these three experiments, the break hole was located at the side, bottom, and top of the horizontal cold leg, respectively. Although the key phenomena observed in the three experiments were basically the same, the break flow rate was affected by the break orientation when phase stratification occured in the cold leg; the break flow rate was largest for the side break and smallest for the top break. The RELAP5/MOD2 code failed to predict the difference in the break flow rate observed in the experiments. Modification to the break flow calculation models, for both subcooled and two-phase flow discharge conditions, resulted in good agreement between data and predictions.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.