Abstract

The aim of this paper is to present the results obtained by the Latin-American and Caribbean personal dosimetry services that participated, with the support of IAEA, in the 2020-Eurados whole-body dosemeter intercomparison for photon radiation. All participant services in this study use thermoluminescent dosimetry (TLD) systems except one that uses optically stimulated luminescence (OSL) dosemeters. Data analysis shows that 93.4% of the results are within the acceptance range, according to International ISO Standard ISO 14146: 2018. The evaluation of the trumpet curves shows that only three laboratories presented a few dosemeters results outside the limits of acceptability. Participation in this Eurados intercomparison exercise gave the Latin American and Caribbean laboratories the opportunity to show compliance with their own quality management system, to compare results with other participants and to develop plans for improving their dosimetry systems. It also gave the assurance that occupational doses are being measured properly and following the international standards in the regions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.