Abstract

Opposition control is a simple feedback control method which can be used to attenuate near-wall turbulence and reduce drag in wall-bounded turbulent flows [H. Choi, P. Moin, and J. Kim, J. Fluid Mech. 262, 75 (1994)]. The idea is to impose blowing and suction at the wall to counteract near-wall quasistreamwise vortical structures. Unfortunately, the effectiveness of this method decreases as the Reynolds number increases [Y. Chang, S. Scott Collis, and S. Ramakrishnan, Phys. Fluids 14, 4069 (2002)]. The present study proposes using a simple modification of opposition control (OC) to increase its performance at high Reynolds numbers. We demonstrate a significant improvement on drag reduction when performing a blowing-only opposition control, where the suction part of OC has been removed, on a spatially developing turbulent boundary layer at Reτ,δ=960, based on the boundary layer thickness and the friction velocity.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.