Abstract

Polycrystalline Pb(Mn0.5W0.5)O3, PMW, a ferroelectric oxide was prepared by high temperature solid state reaction route. In order to reduce the measurement error caused by edge capacitance, laboratory-made three-terminal ring electrode (including a guard terminal) was constructed. A guard ring electrode eliminated parallel resistance paths that could cause errors in materials resistance measurements. Guard ring electrodes were useful devices which enable accurate dielectric measurements to be made on small sample of insulating material. The dielectric constant (ε′) and loss tangent (tan δ) of PMW ceramics were measured as a function of frequency ( 1 kHz- 100 kHz ). The volume resistivity and surface resistivity of PMW ceramics were also investigated. The smallest value of volume and surface resistivity were found to be 1.6 × 10-4 MΩ and 0.1281 MΩ, respectively.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.