Abstract
The problem of Resistance-capacitance (RC) network parameter decoupling estimation is discussed with the background of conductivity measurement. Sinusoidal signal is adopted to excite the RC network, and the response is also the sinusoidal signal which has the same frequency as excitation, but amplitude and phase change. By obtaining the amplitude and phase characteristics of RC network, the value of RC network parameter can be estimated. To eliminate the effect of measurement uncertainty, the multi-sampling of response signal can be used to fit out the function form of response based on the nonlinear least squares method, and then the amplitude ratio and phase difference between response and excitation can be obtained. To ensure the real-time of measurement, gradient method is used to optimization calculation. High measurement accuracy and less iterative times can be achieved, and experimental results show the effectiveness of the proposed method.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.