Abstract

The exhaust heat loss of the power plant boiler can account for more half of the boiler heat loss, exhaust gas temperature is 110~160 °Ccommonly, so the exhaust gas heat can be used to reduce the coal consumption, raise the economic benefits. Before and after the desulfurization tower of a 350 MW unit, there installs two plate heat exchangers, heating condensation water respectively, which can improve the thermal efficiency. With two heat exchangers working under the design conditions, a test was carried out based on a 350 WM unit simulation system in order to test the influence of system for unit operation characteristics. Referring to the data, the investment of the heat exchanger can achieve 2.68 g/kWh coal saving during the non-heating period and 0.2531 g/kWh during the heating period.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.