Abstract

Direct torque control (DTC) has been widely used due to its advantages of less parameter dependence and faster torque response. However, in conventional DTC, there are obvious torque and flux ripples. This paper studies the influence of zero space voltage vectors on DTC system of permanent magnet synchronous motor (PMSM). The control model is established with Matlab/Simulink software. The simulation results show that the ripple torque can be reduced significantly when zero space voltage vectors are used. Meanwhile, the use of zero space voltage vectors can evidently decrease the switching frequency of the power switches as well as the switching loss. The achievements in this paper can provide a reference to improve DTC performance of PMSM.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.