According to the structural characteristics of the axial fan, the causes of equipment resonance are analyzed. Four reference methods are proposed, including strengthen the structural stiffness, change the exciting frequency, weaken the exciting force, and strengthen the damping. The characteristics of the response treatment measures are discussed. Take the two-stage axial-induced draft fan of a 600 MW unit as an example, the axial resonance problem has been dealt with well by improving the support stiffness and reducing the excitation force. The research results and treatment can provide an experience reference for the analysis and treatment of the resonance problem of large axial fans.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.