A non-destructive evaluation system based on high-Tc dc-SQUID (superconducting quantum interference device) incorporating a gradient field excitation has been built. By using this system a 1mm-diameter hole at a depth of 2mm inside an aluminium plate at room temperature can be easily detected and imaged in an unshielded environment. The relation between the spatial resolution, or the smallest detectable flaw size and experimental parameters is briefly analysed in terms of a simple metal ring model. The result shows that the spatial resolution depends strongly on the sensor-sample separation as well as on some other parameters, such as signal-to-noise ratio of excitation, excitation frequency and material conductivity.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.