Abstract

In practical engineering applications, structural fracture failure is caused by slow plastic deformation due to excessive structural stress under large static load.The accurate monitoring and early warning of the structural damage can effectively ensure the efficient service of the structure before the complete fracture of the structure. In this paper, an early-warning method of structural damage based on cointegration theory is proposed. The strain of key positions in structural parts is monitored under the tensile action of large loads, and the damage is judged by the change of the cointegration relationship between strains. Finally, the effectiveness of this method is verified, and the effective monitoring of structural damage is realized through fracture early warning.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.